MOTOR CONTROLMini-Contactors and Thermal Overload RelaysSK Series62C1-E-0022
10 IEC-conformance Ratings (IEC 60947-4-1, EN 60947-4-1, and VDE 0660)TypeMax. motor capacity [kW] Operational current [A]Conventional free air therma
11 IEC-conformance Ratings (Standard Models: Bifurcated Contact)TypeConventional free air thermal current [A](Rated thermal current)Making and breakin
12 AC-operated ModelsType Order voltage Code Coil voltage and frequencySK06ASK09ASK12A24V AC E 24V 50Hz / 24-26V 60Hz48V AC F 48V 50Hz / 48-5
13 AC-operated ModelsType Power consumption [VA] Watt loss [W] Pick-up voltage [V] Drop-out voltage [V]Operating times [ms]SK06ASK09ASK12AInrush Seale
14 SK06 to SK12Type Rated operational voltage [V]Rated operational current [A]Making/breaking current [A] Operating cycles per hour [times/hour]Durabi
15 SK06 to SK12Mini-ContactorsSK SeriesRatings AC-1 Breaking Current and Electrical Durability0.010.11101010.10.01Breaking current [A]1 10 100 1000200
16 Prospective Short-circuit Current “r” (240V and 440V)Magnetic ContactorThermal Overload Relay Coordination typeType 1 Type 2Type Type Ampere settin
17 Rated conditional short-circuit current Iq (240V and 440V)Magnetic ContactorThermal Overload Relay Coordination typeType 1 Type 2Type Type Ampere s
18 Combination of Breaker and FuseMagnetic Starter Short-circuit Current Ratings (SCCR)Magnetic ContactorThermal Overload Relay 240V AC 600V ACType Ty
19 Combinations with Manual Motor StarterMagnetic ContactortypeAC480Y/277VCombined MMS Short-circuit Current Rating (SCCR) [kA]Type Ampere setting ran
2Smallest Mini-Contactors in the World At 45 × 48 × 49mm (W×H×D), these Contactors achieve the same dimensions for AC-operated and DC-operated models.
20 Standard Operating ConditionsAmbient temperature *1−10 to 55°C with no sudden temperature changes resulting in condensation or icing (The average t
21 Wiring and Terminal ProcessingMake all connections correctly according to the connection diagram. For the SK06 to SK12, you can use solid wires, st
22 Handling Thermal Overload Relays1) Adjusting the Current [Figure 1]Turn the adjustment dial within the scale so that the total load current of the
23Mini-ContactorsSK SeriesHandlingExample: Calculation Method for Dial Adjustment at an Ambient Temperature of 55°CDial current at 20°CCompensation co
24SK12LMini-ContactorsSK SeriesMagnetic ContactorsMagnetic Contactors Features International safety standards for standard models (IEC, GB, JIS, UL, a
25 Dimensions, mm Magnetic Contactors SK06□, SK09□, SK12□ Magnetic Starters (reference) SK□ + TK12Mini-ContactorsSK SeriesMagnetic Contactors(34)*1(17
26Reversing Magnetic ContactorsMini-ContactorsSK SeriesReversing Magnetic ContactorsSK12AR Features Ideal for forward/reverse motor operation and plug
2714132T1 4T2 6T3A2A15L33L21L1A2146T34T22T1A1135L33L21L1Coil terminalM3.5Aux. terminalM3.5Main terminalsM3.590.545.5Approx. 5 Approx. 54810.77.78.731*
28TK12Mini-ContactorsSK SeriesThermal Overload RelayThermal Overload Relay Features International safety standards for standard models (IEC, GB, JIS,
29Mini-ContactorsSK SeriesThermal Overload Relay 3-pole CircuitsStandard Operating limit Overload (hot start) Locked rotor (cold start) Ambienttempera
3Easier Wiring①Connection to Round Crimp Terminals②Terminal Arrangement for No Interference between Power Lines for Main and Auxiliary Circuits When W
30TK12Mini-ContactorsSK SeriesThermal Overload Relay Tripping Class 10A TK12 series, Ambient temperature: 20°C Operating Characteristics Curves (Av
31 Type Numbers and Product CodesProduct name Type Specification Used withAuxiliary Contact Blocks(Front mounting, Bifurcated Contact)SZ1KA40Contact ar
32Product name Number of contacts Contact arrangement Mounting Used with TypeAuxiliary Contact Blockswith Bifurcated Contacts4 4NO Front mounting SK06
33Mini-ContactorsSK SeriesAuxiliary Contact Blocks Dimensions, mm4-poleMass : 17gM3.526143038.55.38.81737.7Small,2-poleMass : 29gM3.53 3420.3291238.58
34Set for Power Supply SideSet for Load Side Caution Precaution for Correct Use・When the Magnetic Contactors are switched rapidly, use an electrica
35Product name Rated voltage and frequency Applicable 3-phase motors TypeMain Circuit Surge Suppression Unit 250V AC, 50/60Hz 200 to 240V AC, 0.1 to 2
36Product name Surge suppression elementSpecification Operation indicator lampControl circuit voltage Type AC DCCoil Surge Suppression Units Varistor V
37 Caution Precaution for Correct Use・When mounting the Release, do not allow the lead to bend within 25mm from the panel and within 35mm of the mo
38 Link Module: Electrically and mechanically connects a Manual Motor Starter and Magnetic Contactor.Photo No. KKD11-101Applicable MMS Applicable Magn
39Mini-ContactorsSK SeriesLink Module and Reversing Connection Unit (Insert) BM3RS + SK□ BM3RS + SK□R BM3RH + SK□ BM3RH + SK□R Combination Starter Dim
4Catalog DisclaimerThe information contained in this catalog does not constitute an express or implied warranty of quality, any warranty of merchantab
40Mini-ContactorsSK SeriesAuxiliary Relays Type Number Nomenclature Type Number Nomenclature SK-Series Auxiliary RelaysSKH4 A H - 1 22Basic ty
41SKH4 A H - E 22① ② ③ ④ ⑤Operating coil specification②Contact specification③Coil voltage specification④Contact arrengement⑤Type AC-operated mode
42 Durability (Based on IEC 60947-5-1)Type Number of contactsOperating cycles per hour [times/hour]Mechanical durabilityElectrical durabilityAC-15 AC-
Printed in Japan 2012-10 PDF FOLS 62C1-E-0022Information in this catalog is subject to change without notice.5-7, Nihonbashi Odemma-cho, Chuo-ku, Tok
5Mini-ContactorsSK SeriesPageStandard Models ...
6 Standard ModelsSeries SK SeriesFrame 06 09 12Magnetic Contactor appearance(Photo No. 11-062)Type Magnetic ContactorsAC-operated modelsSK06A SK09A SK
7 Thermal Overload RelaysThermal Overload Relay appearance(Photo No. KKD11-122)TypeTK12Protection Overload and phase-loss protectionAmpere setting ran
8SK 12 A H R - 2 01 WBasic type numberMini-ContactorFrame size06, 09, or 12Operating methodA : AC-operated modelG : DC-operated model (2.4W)L
9TK 12 W A - 009Basic type numberTK : 2E Thermal Overload Relay (with phase-loss detection)MountingW : On-contactor mountingReset methodBlank : M